ResMed has made some key design changes to their already excellent S8 platform of CPAP machines to make them even better.
First, they developed a unique low-inertia, dual-stage motor that rotates at much lower speeds than motors in traditional CPAP devices. Being dual-stage allows it to perform more efficiently at the lower speeds, resulting in exceptionally low noise levels of 26 dB. This revolutionary motor is also encapsulated in a protective silicon envelope that partially inflates with air and further isolates the unit from shock and vibration. ResMed wraps it up in a durable thermoplastic housing for additional protection and sound-deadening. This produces a machine that is noticeably quieter than its competitors.
S8 Escape™ II CPAP delivers ResMed superior quality and reliability in a lightweight, compact flow generator. The S8 Escape™ also provides extra support for clinicians and patients with the S8 Personal Assistant, which notifies patients when it’s time to call their provider, replace their mask, or insert their ResScan data card for remote compliance downloads. In addition to collecting compliance downloads, the ResScan data card can be used to adjust treatment pressure or set the Personal Assistant reminders. Features & Benefits - Small, lightweight system
- Personal Assistant
- Customizable reminders for accessory replacements and provider callbacks
- Automatic data back-up
- LCD communication during interaction
- ResScan Data Card
- Daily compliance downloads with AutoScan software
- Treatment changes
- Personal Assistant reminders
- Pressure ramp (0-45 min)
- 12/24V DC power input
- Automatic power adjustment (100V-240V)
- Manual altitude adjustment
Large LCD screen
Specifications
Performance: Operating pressure range: 4 to 20 cm H2O Dimensions (H x W x D): 4.6” x 6.5” x 5.7” (112 mm x 164 mm x 145 mm) Weight: 2.9lb (1.3 kg) Power Supply Input range: - 100–240V, 50/60Hz; 110V, 400Hz; 2.5A
- Refer to the DC-12 converter instructions for DC ratings. Only use the ResMed DC-12 converter for DC input.
Actual power consumption will vary depending on factors such as the use of accessories, height above sea level, and ambient temperature. Power consumption values for typical treatment conditions (using a breathing machine set to 0.5 L and 15 breaths/min with 2 m (6’ 6”) air tubing and an Ultra MirageTM mask) are given in the following table.
| Device | Pressure (cm H2O) | Power (VA) | Power (W) | | | 5 | 17 | 8 | | | 10 | 23 | 12 | | | 15 | 29 | 16 | | | 20 | 34 | 20 | Power outlet for Accessory Note: Accessory currently not available. Outlet range: 100–240V, 50/60Hz; 110V, 400Hz; 2.0A Air Filter: Two-layered, powder-bonded, polyester non-woven fiber Air Tubing: Flexible plastic, 2 m (6’ 6”) IEC 60601-1 Classifications: Class II (double insulation), Type CF Accessories Data Card Dimensions (L x W x D): 2.56” x 0.87” x 0.03” (65.04 mm x 22.15 mm x 0.85 mm)
Data Card Module Dimensions (H x W x D): 1.95” x 1.66” x 0.47” (49.7 mm x 42.2 mm x 12 mm)
All Devices (Where Applicable) Housing Construction: Flame retardant engineering thermoplastic Environmental Conditions Operating Temperature: +41°F to +104°F (+5°C to +40°C) Operating Humidity: 10%–95% non-condensing Storage and Transport Temperature: -4°F to +140°F (-20°C to +60°C) Storage and Transport Humidity: 10%–95% non-condensing Operating Altitude: sea level to 8500’ (2591 m) Electromagnetic Compatibility Product complies with all applicable electromagnetic compatibility requirements (EMC) according to IEC60601-1-2, for residential, commercial, and light industry environments. |